Controller (MAM Series)

MAM_890

MAM 890

ModelCurrent Range Corresponding main motor power (KW)Remark
MAM 890 (20)80-20Below 11 
MAM 890 (40)16-4011-18.5 
MAM 890 (100)10022-45 
MAM 890 (200)20055-90 
MAM 890 (400)400110 
MAM 860 (600/5)600/5200-250With CT 
MAM_860

MAM 860

ModelCurrent Range Corresponding main motor power (KW)RemarkDescription
MAM 860 (20)80-20Below 11 Fan has three
levels of current,
such as 0.2-2.5A,
1-5A and 4-10A,
determined-by
current of motor
MAM 860 (40)16-4011-18.5 
MAM 860 (100)10022-45 
MAM 860 (200)20055-90 
MAM 860 (400)400110 
MAM 860 (600/5)600/5200-250With CT 
MAM_880

MAM 880

ModelCurrent Range Corresponding main motor power (KW)RemarkDescription
MAM 880 (20)80-20Below 11 Fan has three
levels of current,
such as 0.2-2.5A,
1-5A and 4-10A,
determined-by
current of motor
MAM 880 (40)16-4011-18.5 
MAM 880 (100)10022-45 
MAM 880 (200)20055-90 
MAM 880 (400)400110 
MAM 880 (600/5)600/5200-250With CT 
MAM_6070

MAM 6070

ModelCurrent Range Corresponding main motor power (KW)RemarkDescription
MAM 6070 (20)80-20Below 11 Fan has three
levels of current,
such as 0.2-2.5A,
1-5A and 4-10A,
determined-by
current of motor
MAM 6070 (40)16-4011-18.5 
MAM 6070 (100)10022-45 
MAM 6070 (200)20055-90 
MAM 6070 (400)400110 
MAM 6070 (600/5)600/5200-250With CT 
MAM_6080

MAM 6080

ModelCurrent Range Corresponding main motor power (KW)RemarkDescription
MAM 6070 (20)80-20Below 11 Fan has three
levels of current,
such as 0.2-2.5A,
1-5A and 4-10A,
determined-by
current of motor
MAM 6080 (40)16-4011-18.5 
MAM 6080 (100)10022-45 
MAM 6080 (200)20055-90 
MAM 6080 (400)400110 
MAM 6080 (600/5)600/5200-250With CT 
MAM_6090

MAM 6090

ModelCurrent Range Corresponding main motor power (KW)RemarkDescription
MAM 6090 (20)80-20Below 11 Fan has three
levels of current,
such as 0.2-2.5A,
1-5A and 4-10A,
determined-by
current of motor
MAM 6090 (40)16-4011-18.5 
MAM 6090 (100)10022-45 
MAM 6090 (200)20055-90 
MAM 6090 (400)400110 
MAM 6090 (600/5)600/5200-250With CT 

How to select the right MAM controller

The MAM range covers the controllers used on the majority of our machines. Selection is by the current range of the main motor, because that is what the controller measures and protects.

  • Current ratings — 20 A (motors below 11 kW), 40 A (11–18.5 kW), 100 A (22–45 kW), 200 A (55–90 kW) and 400 A (110 kW and above). The 600/5 version is used with an external CT on the largest machines.
  • Models — MAM 890, 860, 880, 6070, 6080 and 6090. The families differ in display, I/O count and the fan control, so ask for the model that was originally fitted rather than the nearest one.
  • Fan output — the 860 / 880 / 6070 / 6080 / 6090 families offer three fan current levels (0.2–2.5 A, 1–5 A, 4–10 A), set according to the fan actually fitted.
  • Voltage — 220 V control as standard; specify when the machine is built for another supply.

Installation and maintenance

  • Record the parameter set of the old controller before removing it. Most “new controller does not work” calls are a missing parameter, not a faulty unit.
  • Current transformers must be fitted in the right direction and the ratio entered correctly, or the machine will trip on overload at half load.
  • Keep the controller wiring separated from the variable-speed drive output; induced noise on the sensor inputs shows up as random temperature or pressure faults.
  • After fitting, run the machine through load, unload, stop and a fault simulation before handing it back.

Mam controller FAQ

The model is printed on the controller face or on the label on its side. Send a photo of the label — the current rating and the model together identify the replacement.

Not safely. The current range has to cover the motor; a controller rated below the motor current will trip in normal operation. Go up a size if the exact one is not available.

It is supplied with the standard parameter set; the machine-specific parameters (pressure band, timings, current ratio) are entered at commissioning. We can pre-load them if you send the parameter list.