Centrifugal Fan

centrifugal_fan_YWFF200
centrifugal_fan_YWFF200_data

YWFF 200

centrifugal_fan_YWFF200_drawomg

ModelVoltage(V)Frequency (HZ)Current (A)Input Power (W)Speed (RPM)Max Air Flow (m³/h)Capacitor (µF)Noise (db)
YWFF4E200230501.360.3313001300660
YWFF4D200Δ230/Y400501.7/1.00.3313001300/60
centrifugal_fan_YWFF200
centrifugal_fan_YWFF225_data

YWFF 225

centrifugal_fan_YWFF225_drawomg

ModelVoltage(V)Frequency (HZ)Current (A)Input Power (W)Speed (RPM)Max Air Flow (m³/h)Capacitor (µF)Noise (db)Curve
YWFF4E225230502.30.4813501800850①
YWFF4D225Δ230/Y400501.42/0.810.4413501800/60②
YWFF6E225230501.30.239301300670④
YWFF6D225Δ230/Y400501.36/0.80.249301300/70③

 

centrifugal_fan_YWFF250
centrifugal_fan_YWFF250_data

YWFF 250

centrifugal_fan_YWFF250_drawing

ModelVoltage(V)Frequency (HZ)Current (A)Input Power (W)Speed (RPM)Max Air Flow (m³/h)Capacitor (µF)Noise (db)Curve
YWFF4E250230503.30.75133024501660①
YWFF4D250Δ230/Y400503.0/1.700.813502600/70②
YWFF6E250230501.60.299101700570④
YWFF6D250Δ230/Y400500.75/1.30.279101700/70③
centrifugal_fan_YWFF250
centrifugal_fan_YWFF280_data

YWFF 280

centrifugal_fan_YWFF280_drawing

ModelVoltage(V)Frequency (HZ)Current (A)Input Power (W)Speed (RPM)Max Air Flow (m³/h)Capacitor (µF)Noise (db)Curve
YWFF4E280230505.41.2140035003050①
YWFF4D280Δ230/Y400504.3/2.51.3514003700/60②
YWFF6E2802305020.469002400870③
YWFF6D280Δ230/Y400501.5/0.90.479002400/70③
centrifugal_fan_YWFF250
centrifugal_fan_YWFF315_data

YWFF 315

centrifugal_fan_YWFF315_drawing

ModelVoltage(V)Frequency (HZ)Current (A)Input Power (W)Speed (RPM)Max Air Flow (m³/h)Capacitor (µF)Maximum ambient temperature (℃)CurveNoise (db)
YWFF4E315230508.82140043005040①83
YWFF4D315Δ230/Y400506.6/3.9214004300/60①83
YWFF6E315230503.10.7293034001270②73
YWFF6D315Δ230/Y400503.2/1.90.739303400/70③73
centrifugal_fan_YWFF250
centrifugal_fan_YWFF355_data

YWFF 355

centrifugal_fan_YWFF355_drawing

ModelVoltage(V)Frequency (HZ)Current (A)Input Power (W)Speed (RPM)Minimum Static PressureMax Air Flow (m³/h)Curve
YWFF4D355Δ230/Y400509.7/5.7314004005700①
YWFF6D355Δ230/Y400503.9/2.319001503900②
centrifugal_fan_YWFF400
centrifugal_fan_YWFF400_data

YWFF 400

centrifugal_fan_YWFF400_drawing

ModelVoltage(V)Frequency (HZ)Current (A)Input Power (W)Speed (RPM)Max Air Flow (m³/h)Maximum ambient temperature (℃)Curve
YWFF4D400Δ230/Y4005012.8/7.54.41370690045①
YWFF6D400Δ230/Y400508.5/52.2900705060②
YWFF8D400Δ230/Y400506/3.51.2650600055③
centrifugal_fan_YWFF400
centrifugal_fan_YWFF450_data

YWFF 450

centrifugal_fan_YWFF450_drawing

ModelVoltage(V)Frequency (HZ)Current (A)Input Power (W)Speed (RPM)Max Air Flow (m³/h)Maximum ambient temperature (℃)Curve
YWFF4D450Δ230/Y4005013.9/8.251380660040①
YWFF6D450Δ230/Y4005010.4/6.13.5870810040②
YWFF8D450Δ230/Y400507/4.11.4700610040③

How to select the right centrifugal fan

These are the external rotor centrifugal fans used for canopy cooling and ducted ventilation on screw compressors. The model number carries the impeller size; the letter after the size is the voltage and speed code.

  • Range — YWFF 200, 225, 250, 280, 315, 355, 400 and 450, with air flow from about 1300 to 8100 m³/h.
  • Voltage — the E models are single phase 230 V with a capacitor; the D models are Δ230 V / Y400 V three phase, so they can be connected to either supply.
  • Speed — the 4-pole versions run around 1300–1400 rpm, the 6-pole versions around 900 rpm at lower noise and lower flow.
  • Noise — 50–83 dB(A) depending on size and speed; if the machine has a noise limit, take the 6-pole version and a larger impeller rather than running a small 4-pole fan fast.

Installation and maintenance

  • Fit the fan so that it pulls air through the cooler and pushes it out of the canopy — reversing it cuts the airflow by roughly a third.
  • Leave the clearance the drawing gives around the impeller; a fan pressed against a panel stalls and the motor then runs hot.
  • On single-phase models the capacitor is part of the circuit — a fan that hums and does not start is usually the capacitor, not the motor.
  • Check the rotation direction before the canopy goes back on; three-phase fans run backwards on two of three wiring combinations.

Centrifugal fan FAQ

By noise and by the pressure the duct needs. The 4-pole fan moves more air for its size but is louder; the 6-pole version is quieter and is the usual choice for a machine installed near people.

Yes — the D models are Δ230 V / Y400 V, so they connect to a 380–400 V three-phase supply in star. Check the terminal link position before switching on.

Usually the air path is the problem, not the fan. Check the cooler fins, the intake louvres and the recirculation inside the canopy before fitting a bigger fan.