ANKA RH SERIES INTAVE VALVE

rh_intake_valve_40
rh_intake_valve_50
rh_intake_valve_65
rh_intake_valve_90
rh_intake_valve_40
rh_intake_valve_50
rh_intake_valve_65
rh_intake_valve_90
rh_intake_valve_40
rh_intake_valve_50
rh_intake_valve_65
rh_intake_valve_90
previous arrow
next arrow

Advantage

Features:

  • Application: Variable Speed Oil-injected Screw Compressor
  • Release Mode: Controlled by Airend Suction Port Pressure at Shutdown or by Solenoid Valve.
  • Intake Valve Has Hammer Type Check Structure of Low Pressure Loss to Prevent Oil Injection Through the Compressor at Shutdown.
  • Unique Discharge Flow Channel Direction Leads Airflow Not to Wash Check Valve Plate During Discharging.
  • Integration of Discharge Valve, and Electric Control Solenoid Valve Makes It Install Easily and Quickly.

Model Description:

RH_intake_valve_description

Technic Data:

Model DiameterFlow(m³/min)Maximum Working PressureWorking Medium TemperatureWorking Temperature
RH-40H402-4.516-20-120-20-60
RH-50B503-616-20-120-20-60
RH-50D503-616-20-120-20-60
RH-65B655-1016-20-120-20-60
RH-65D655-1016-20-120-20-60
RH-90B909-1916-20-120-20-60
RH-90D509-1916-20-120-20-60
rh_intake_valve_drawing
ModelABCDEFInterface SizeO-Ring SizeG
RH-40H125*12586ø109ø13210848RP1/482*2.654-ø13
RH-50B132*132100ø135ø15018262RP1/2 RP1/8110*3.54-ø17
RH-50D132*132100ø135ø15018262RP1/4110*3.54-ø17
RH-65B150*150110ø143ø17015178RP1/2 RP1/8118*3.54-ø17
RH-65D150*150110ø143ø17015178RP1/4118*3.54-ø17
RH-90B155*155120ø160ø180226100RP1/2 RP1/8132*3.554-ø17
RH-90D155*155120ø160ø180226100RP1/4132*3.554-ø17

How to select the right RH series intake valve

The RH series is built for variable-speed oil-injected compressors. The release is controlled either by the airend suction-port pressure at shutdown or by a solenoid valve, and the check element is a hammer-type plate with a low pressure loss.

  • Models and flow — RH-40H 2–4.5 m³/min, RH-50B / 50D 3–6, RH-65B / 65D 5–10, RH-90B / 90D 9–19.
  • B and D suffix — the difference is the pilot interface: B uses RP1/2 with an RP1/8 signal port, D uses RP1/4. Choose by the control line on the machine.
  • Rating — 16 bar, medium temperature −20 to 120 °C, ambient −20 to 60 °C.
  • Flange — each model has its own bolt pattern and O-ring size (for example RH-65B: 150×150 flange, 4-ø17, O-ring 118×3.5). Match the flange, not just the bore.

Installation and maintenance

  • The discharge channel is shaped so that the airflow does not wash the check plate while discharging — keep the valve the right way round, the arrow on the body is the only guide you need.
  • The integrated solenoid and discharge valve save piping, but they also mean the pilot air must be dry. Fit the filter on the pilot line.
  • At shutdown the hammer check closes on pressure loss from the airend side. If oil appears in the intake after stopping, check that the check plate is free to move and has not been glued by oil sludge.
  • Use a new O-ring on the flange every time the valve is removed; a reused O-ring that has hardened is the usual cause of a leak after a service.

Rh series intake valve FAQ

RH is intended for variable-speed machines, with release by suction pressure or solenoid; AIV is a normally-open valve for fixed-speed machines that closes on a control signal. The body shapes and the flange patterns differ, so they are not interchangeable.

Often it is. The check plate can chatter if the pilot pressure is unstable or the plate is worn. Check the pilot filter and the plate first, then the solenoid response time.

Look at the control port on the old valve: B has an RP1/2 main pilot port plus RP1/8 signal, D has RP1/4. Send a photo of the old valve if you are not sure.